Quantcast

Honeywell 5604 System Sensor 194°F Fixed Temperature, Single-Circuit Heat Detector

Honeywell 5604 System Sensor 194°F Fixed Temperature Heat Detector
Honeywell 5604 System Sensor 194°F Fixed Temperature Heat Detector
Item# 5604
List Price: $15.64
Your Price: $10.43

System Sensor 5604 Product Description:


The System Sensor 5604 is a 5600-series, 194°F fixed temperature, single-circuit, mechanical heat detector. The 5604 detector offers a low-cost means for property protection against fire, and for non-life-safety installations where smoke detectors are inappropriate. Add the hardwired 5604 heat detector to most existing alarm system control panels.

To satisfy a variety of installation needs, the 5604 easily mounts to single-gang and octagonal back boxes. And the 5604 accommodates four-square back boxes, when used with a square to round plaster ring. The reversible mounting bracket permits both flush and surface-mount back box installations.

The 5604 provides clear markings on the exterior of the unit to ensure that the proper detector is being used. Alphanumeric characters identify the activation method, as well as the temperature rating, in Fahrenheit and Celsius degrees. The 5604 is a fixed temperature model and identified by an FX. The 5604 also provides a post-activation indicator in the form of a collector. When the detector is activated, the collector drops from the unit, making it easy to identify the unit in alarm.

Product Features:
  • Multiple configurations for installations: Single-circuit model, Fixed temp 194°F rating
  • Easy-to-use terminal screws
  • A broad range of back box mounting options: Single gang, 3.5" and 4" Octagonal, 4" square with square to round plaster ring
  • Reversible mounting bracket

System Sensor 5604 Product Specifications:


  • Dimensions (w/Mounting Bracket): 1.69" (4.3cm) Height x 4.57" (11.6cm) Diameter
  • Heat Sensor: 150°F (57°C) fixed temperature
  • Maximum Installation Temperature: 150°F (65.6°C)
  • Operating Temperature Range: 32° to 100°F (0° to 38°C)
  • Alarm Temperature: 135°F (57°C)
  • Operating Humidity Range: 5% to 95% Relative Humidity noncondensing
  • Single Gang: Yes
  • Wiring: Single-Circuit
  • Wiring Gauge: 14-22 AWG
  • Mounting: 3½-inch octagonal back box, 4-inch octagonal back box, Single gang back box, 4-inch square back box with a square to round plaster ring
  • Operating Voltage: 6-125VAC / 3A
  • Ratings: 6-28VDC / 1A, 125VDC / 0.3A, 250VDC / 0.1A
  • Input Terminals: 1422 AWG
  • Activation: Fixed Temperature
  • UL Protected Spacing (10 Foot Ceiling): 25 feet 25 feet (7.62m 7.62m)
  • Weight: 6 oz. (170 g)

Q & A's : System Sensor 5603 Fixed-Temperature Heat Detector