844-335-5897

MN02-LTE-M-AV - M2M Universal Multi-Band Cellular AT&T/Verizon LTE-M Alarm Communicator (Compatible with Most Panels)

MN02-LTE-M-AV - M2M Universal Multi-Band Cellular AT&T/Verizon LTE-M Alarm Communicator (Compatible with Most Panels)
MN02-LTE-M-AV - M2M Universal Multi-Band Cellular AT&T/Verizon LTE-M Alarm Communicator (Compatible with Most Panels)
Item# MN02-LTE-M-AV
List Price: $119.99
Your Price: $79.99
Cellular Radio Antenna Length: 
Availability: In Stock
QTY:

* The part listed above requires a subscription to M2M Services powered by AlarmClub.

M2M Services MN02-LTE-M-AV Product Description:


The M2M Services MN02-LTE-M-AV is a universal multi-band cellular alarm communicator that is compatible with most existing dial-capture interface burglary intrusion control panels (DSC, Honeywell and GE Interlogix NX-Series). With future-proof technology, the MN02-LTE-M-AV communicator transmits alarm signals over the AT&T/Verizon LTE network to the AlarmClub central monitoring station.

Likewise, the MN02-LTE-M-AV can be accessed remotely by an AlarmClub professional technician using UDL software (DLS, Compass, DL900) via the RING/TIP connections (using the MN01-RNGR module). So, have peace of mind knowing you are not alone, and this communicator allows for our remote panel programming and full upload/download remote capabilities.

Additionally, the MN02-LTE-M-AV communicator has the ability for end users to remotely control some of the interactive features using the RControl smartphone app (designed for Android/iPhone). Using the app clients can have; remote arm/disarm capabilities, real-time push and email notifications, multiple end users and devices per account, 12 months events history and basic configuration/diagnostics.

In summary, the MN02-LTE-M-AV is a inexpensive option for our DIY clients who have existing security systems and are looking to lower their business or home security bill. This new age M2M Verizon LTE (Long-Term Evolution) communicator, powered by GeoArm, brings faster speeds and greater stability that won't break the bank.

Product Features:

  • Universal Panel Compatibility: Dial-Capture Interface supporting Contact ID, SIA and Pulse 4+2
  • Future-proof LTE-M technology: Dual SIM supporting both AT&T and Verizon (or any country specific networks) in the same radio
  • Interactive features: Smartphone app for end users and Admin app for installers
  • Remote panel programming: Upload/Download via Tip & Ring for selected panels

*If ordered, the M2M cellular radio antenna manufactured in the 10' foot length is subject to product availability.

M2M Services MN02-LTE-M-AV Product Specifications:


  • CAT-M1 LTE 700/850/1700/1900/2100 MHz cellular communicator for AT&T/Verizon
  • Dual SIM, supporting AT&T and Verizon
  • ARM11 processor, 2MB RAM, 7MB Flash
  • Dial Capture interface supporting Ademco ContactID, SIA and Pulse 4+2
  • Remote Upload/Download for selected Honeywell, DSC, Interlogix alarm panels (requires an add-on module)
  • Keybus integration with selected Honeywell and DSC panels
  • 1 digital input, 1 digital output (programmable)
  • Ultra-Compact Dimensions: 1.6" x 1.95" x 0.82"
  • Supply voltage: +12 to +17 VDC
  • Power Consumption: Nominal 15mA, Peak 200 mA
  • Weight: 1.1 oz (30 g) without an antenna

M2M Services MN02-LTE-M-AV Product Documents:


General Information

Product Datasheet - M2M Services MN02-LTE-M-AV Universal Multi-Band Cellular Verizon LTE Alarm Communicator
Installation/Operation Manual - M2M Services MN02-LTE-M-AV Universal Multi-Band Cellular Verizon LTE Alarm Communicator
Quick Installation Manual - M2M Services MN02-LTE-M-AV Universal Multi-Band Cellular Verizon LTE Alarm Communicator

DSC Control Panel Programming and Wiring Guides

How to Programming/Wiring Guide - M2M Services MN02-LTE-M Multi-Band Cellular Verizon LTE Alarm Communicator to the DSC PowerSeries 9045/9047 Control Panel
How to Programming/Wiring Guide - M2M Services MN02-LTE-M Multi-Band Cellular Verizon LTE Alarm Communicator to the DSC Alexor Control Panel
How to Programming/Wiring Guide - M2M Services MN02-LTE-M Multi-Band Cellular Verizon LTE Alarm Communicator to the DSC Impassa Control Panels (SCW9057/SCW9057)
How to Programming/Wiring Guide - M2M Services MN02-LTE-M Multi-Band Cellular Verizon LTE Alarm Communicator to the DSC PowerSeries Neo Control Panels (HS2016/HS2032/HS2064/HS2128)
How to Programming/Wiring Guide - M2M Services MN02-LTE-M Multi-Band Cellular Verizon LTE Alarm Communicator to the DSC PC585 Control Panel
How to Programming/Wiring Guide - M2M Services MN02-LTE-M Multi-Band Cellular Verizon LTE Alarm Communicator to the DSC PowerSeries PC1616/PC1832/PC1864 Control Panels
How to Programming/Wiring Guide - M2M Services MN02-LTE-M Multi-Band Cellular Verizon LTE Alarm Communicator to the DSC PC4020 Maxsys Control Panel
How to Programming/Wiring Guide - M2M Services MN02-LTE-M Multi-Band Cellular Verizon LTE Alarm Communicator to the DSC Power832 PC5010 Control Panel

Honeywell Control Panel Programming and Wiring Guides

How to Programming/Wiring Guide - M2M Services MN02-LTE-M Multi-Band Cellular Verizon LTE Alarm Communicator to the Honeywell FA147C/FA148C Control Panel
How to Programming/Wiring Guide - M2M Services MN02-LTE-M Multi-Band Cellular Verizon LTE Alarm Communicator to the Honeywell FA162 Control Panel
How to Programming/Wiring Guide - M2M Services MN02-LTE-M Multi-Band Cellular Verizon LTE Alarm Communicator to the Honeywell VISTA 10PSIA Control Panel
How to Programming/Wiring Guide - M2M Services MN02-LTE-M Multi-Band Cellular Verizon LTE Alarm Communicator to the Honeywell VISTA 10SE Control Panel
How to Programming/Wiring Guide - M2M Services MN02-LTE-M Multi-Band Cellular Verizon LTE Alarm Communicator to the Honeywell VISTA 15P/20P Control Panel
How to Programming/Wiring Guide - M2M Services MN02-LTE-M Multi-Band Cellular Verizon LTE Alarm Communicator to the Honeywell VISTA 15SE Control Panel
How to Programming/Wiring Guide - M2M Services MN02-LTE-M Multi-Band Cellular Verizon LTE Alarm Communicator to the Honeywell VISTA 20PSIA Control Panel
How to Programming/Wiring Guide - M2M Services MN02-LTE-M Multi-Band Cellular Verizon LTE Alarm Communicator to the Honeywell VISTA 20SE Control Panel
How to Programming/Wiring Guide - M2M Services MN02-LTE-M Multi-Band Cellular Verizon LTE Alarm Communicator to the Honeywell VISTA 21IP Control Panel
How to Programming/Wiring Guide - M2M Services MN02-LTE-M Multi-Band Cellular Verizon LTE Alarm Communicator to the Honeywell VISTA 32FB/128FBP Control Panel
How to Programming/Wiring Guide - M2M Services MN02-LTE-M Multi-Band Cellular Verizon LTE Alarm Communicator to the Honeywell VISTA 50P Control Panel
How to Programming/Wiring Guide - M2M Services MN02-LTE-M Multi-Band Cellular Verizon LTE Alarm Communicator to the Honeywell VISTA 128BP Control Panel
How to Programming/Wiring Guide - M2M Services MN02-LTE-M Multi-Band Cellular Verizon LTE Alarm Communicator to the Honeywell VISTA 128SIA Control Panel

GE Interlogix Control Panel Programming and Wiring Guides

How to Programming/Wiring Guide - M2M Services MN02-LTE-M Multi-Band Cellular Verizon LTE Alarm Communicator to the GE Interlogix Concord 4 Control Panel
How to Programming/Wiring Guide - M2M Services MN02-LTE-M Multi-Band Cellular Verizon LTE Alarm Communicator to the GE Interlogix Concord Express Control Panel
How to Programming/Wiring Guide - M2M Services MN02-LTE-M Multi-Band Cellular Verizon LTE Alarm Communicator to the GE Interlogix NetworX NX-4 Control Panel
How to Programming/Wiring Guide - M2M Services MN02-LTE-M Multi-Band Cellular Verizon LTE Alarm Communicator to the GE Interlogix NetworX NX-6V2 Control Panel
How to Programming/Wiring Guide - M2M Services MN02-LTE-M Multi-Band Cellular Verizon LTE Alarm Communicator to the GE Interlogix NetworX NX-8 Control Panel
How to Programming/Wiring Guide - M2M Services MN02-LTE-M Multi-Band Cellular Verizon LTE Alarm Communicator to the GE Interlogix NetworX NX-8E Control Panel
How to Programming/Wiring Guide - M2M Services MN02-LTE-M Multi-Band Cellular Verizon LTE Alarm Communicator to the GE Interlogix Simon XT Control Panel

Paradox Control Panel Programming and Wiring Guides

How to Programming/Wiring Guide - M2M Services MN02-LTE-M Multi-Band Cellular Verizon LTE Alarm Communicator to the Paradox Digiplex EVO 192 Control Panel
How to Programming/Wiring Guide - M2M Services MN02-LTE-M Multi-Band Cellular Verizon LTE Alarm Communicator to the Paradox Digiplex EVO HD Control Panel
How to Programming/Wiring Guide - M2M Services MN02-LTE-M Multi-Band Cellular Verizon LTE Alarm Communicator to the Paradox SP728/SP738 Control Panel
How to Programming/Wiring Guide - M2M Services MN02-LTE-M Multi-Band Cellular Verizon LTE Alarm Communicator to the Paradox SP1738 Control Panel
How to Programming/Wiring Guide - M2M Services MN02-LTE-M Multi-Band Cellular Verizon LTE Alarm Communicator to the Paradox SP4000 Control Panel
How to Programming/Wiring Guide - M2M Services MN02-LTE-M Multi-Band Cellular Verizon LTE Alarm Communicator to the Paradox SP5500 Control Panel

Napco Control Panel Programming and Wiring Guides

How to Programming/Wiring Guide - M2M Services MN02-LTE-M Multi-Band Cellular Verizon LTE Alarm Communicator to the Napco Gemini GEM 1632 Control Panel

DMP Control Panel Programming and Wiring Guides

How to Programming/Wiring Guide - M2M Services MN02-LTE-M Multi-Band Cellular Verizon LTE Alarm Communicator to the DMP XR20/XR40 Control Panel
How to Programming/Wiring Guide - M2M Services MN02-LTE-M Multi-Band Cellular Verizon LTE Alarm Communicator to the DMP XR150 Control Panel
How to Programming/Wiring Guide - M2M Services MN02-LTE-M Multi-Band Cellular Verizon LTE Alarm Communicator to the DMP XT30D/XT50DN Control Panel

Elk Control Panel Programming and Wiring Guides

How to Programming/Wiring Guide - M2M Services MN02-LTE-M Multi-Band Cellular Verizon LTE Alarm Communicator to the Elk M1 Control Panel
Q & A's :

comments powered by Disqus