The Honeywell's VISTA 128BPT is a powerful member of the Honeywell family of commercial alarm panels, integrating burglary intrusion, CCTV and access control categories. There are many features that are available which extend the applications of the Honeywell VISTA 128BPT while simplifying end-user operation. The control panel's installation advantages, innovative end-user benefits and robust system capacity make the value-priced VISTA-128BPT an ideal choice for higher end installations.
The Honeywell VISTA 128BPT is listed for residential burglary, residential fire and commercial burglary applications. The VISTA 128BPT is compatible with a wide range of AlarmNet Total Connect communications products for alarm reporting, uploading /downloading and remote services provided by AlarmClub Security.
UL609 Grade A Local Mercantile Premises and Mercantile Safe and Vault
UL1610 Grades A, AA Central Station
UL365 Grades A, AA Police Connect
UL985 Household Fire
UL1023 Household Burglar Alarm California State Fire Marshall (CSFM)
UL1635 - Digital Alarm Communicator System Units
CAN/ULC - S303
CAN/ULC - S304
CAN/ULC - S545
CAN/ULC - S1023
For commercial burglary attack proof requirements, use N5873V4BE attack proof enclosure provided in VISTA-ULKT kit
Electrical:
Voltage Input: From Honeywell Home No. 1361 Plug-In Transformer or 1361X10 transformer (for X-10 installations) rated 16.5VAC, 40 VA
Use 1361CN plug-in transformer for Canada
Alarm Sounder Output: 10VDC-13.8VDC, 1.7 amps max., (UL1023, UL609 installations); 750mA less aux. current draw (UL985 installations)
Auxiliary Power Output: 9.6VDC13.8VDC, 750mA max. For UL installations, the accessories connected to the output must be UL Listed, and rated to operate in the above voltage range
Backup Battery: 12VDC, 4AH or 7AH sealed-lead acid. YUASA NP4-12 (12V, 4AH) or NP7-12 (12V, 7AH) recommended
Standby Time: Four hours min. with 750mA aux. load using 7AH battery
Circuit Protectors: PTC circuit breakers are used on battery input to protect against reverse battery connections and on alarm sounder output to protect against wiring faults (shorts). A solid state circuit breaker is used on auxiliary power output to protect against wiring faults (shorts).
Main Dialer:
Formats Supported: ADEMCO Contact ID with support for four-digit and tendigit accounts and ADEMCO 4 + 2 Express
Basic Hardwired Zones:
Provides nine style-B hardwired zones with the following characteristics:
• EOLR supervision (optional for zones 2-8) supporting N.O. or N.C. sensors (EOLR supervision required for fire and UL burglary installations)
• Individually assignable to one of eight partitions
• Up to 16 two-wire smoke detectors on zone 1
• Four-wire smoke or heat detectors on zones 1-8 (power to four-wire smoke detectors must be supervised with an EOL device). Listed for residential fire only.
Polling Loop Expansion:
Supports up to 119 additional zones using a built-in polling (V-Plex, multiplex) loop interface. Current draw can total up to 128mA. Polling loop zones have the following characteristics:
• Must use V-Plex devices
• Supervised by control panel
• Individually assignable to one of eight partitions
• Supports VSI Module
• Supports 4297 Expander Module
• Maximum wiring distance = 12,000 feet
Wireless Expansion:
Supports up to 127 wireless zones using up to two 5800-Series wireless receivers (fewer if using hardwire and/or polling loop zones). Wireless zones have the following characteristics:
• Supervised by control panel for check-in signals (except certain nonsupervised transmitters)
• Tamper protection for supervised transmitters
• Individually assignable to one of eight partitions
Scheduling:
Provides the following scheduling capabilities:
• Open/close schedules (for control of arming/disarming and reporting)
• Holiday schedules (allows different time windows for open/close schedules)
• Timed events (for activation of relays, auto-bypassing and unbypassing, auto-arming and disarming, etc.)
• Access schedules (for limiting system access to users by time)
• End user output programming mode (provides 20 timers for output control)
Eight Partitions:
Provides the ability to control eight separate areas independently, each functioning as if it had its own separate control. Partitioning features include:
• A Common Lobby partition (1-8), which can be programmed to arm automatically when the last partition that shares the common lobby is armed, and to disarm when the first partition that shares the common lobby is disarmed
• A Master partition (9), used strictly to assign keypads for the purpose of viewing the status of all eight partitions at the same time (master keypads)
• All zones assignable to one of eight partitions
• Keypads assignable to one of eight partitions or to Master partition 9 to view system status
• Ability to assign relays to one or all eight partitions
• Ability to display fire and/or burglary and panic and/or trouble conditions at all other partitions' keypads (selectable option)
• Individually programmable account number, entry delay and exit delay by partition
id:vista-128bpt-honeywell-turbo-control-panel|image:https://s.turbifycdn.com/aah/yhst-39386722855626/vista-128bpt-honeywell-home-hardwired-commercial-alarm-control-panel-57.png|name:VISTA 128BPT - Honeywell Home Hardwired Commercial Alarm Control Panel|price:378.14|rating:0|rollimage:|brand:Honeywell Home|price:567.2|frequency:|installation:PRO Install|wired-zones:Up to 128 Zones|wireless-zones:Up to 128 Zones|color:|compatible:|network:|resolution:|monitoring-type:|property-type:|communication:|supervision-test:|interactive-app:|environment: